How To Change The Battery In A Braunthermoscan Model Hm3

Teaching Manual

ThermoScan 3 Thermometer

ThermoScan 3 Thermometer
Model: IRT 3030

This product is manufactured by
Kaz Europe Sàrl under a license
to the 'Braun' trademark. 'Braun' is a
registered trademark of Braun GmbH,
Kronberg , Germany.
ThermoScan is a registered trademark
of Kaz Europe Sàrl

Product Description

Product Description

1. Protective cap
2. Dispensable lens filter
3. Probe
4. «kickoff» button
5. Probe tip (lens)
6. Lens filter detector
seven. Display
viii. Battery door safety lock
nine. Battery door (i X 3V type 2032 battery)

The Braun ThermoScan® thermometer is indicated for intermittent measurement and monitoring of human trunk temperature for people of all ages.

Important safety data

Delight consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, aridity, changes in ambition or activity, seizure, musculus hurting, shivering, stiff neck, pain when urinating, etc. in spite of absenteeism of fever.

The operating ambient temperature range for this thermometer is x – 40 °C (50 – 104 °F).

Exercise non expose the thermometer to temperature extremes (beneath –25 °C / –13 °F or over 55 °C / 131 °F) or excessive humidity (> 95 % RH). This thermometer must only be used with 18-carat Braun ThermoScan® dispensable lens filters. Other lens filters can pb to inaccuracy.

To avoid inaccurate measurements always apply this thermometer with a new, make clean, disposable lens filter. If the thermometer is accidentally used without a disposable lens filter, clean the lens after use (see «Care and cleaning»).

Keep disposable lens filters out of attain of children. This thermometer is intended for household utilise just.

Apply of this thermometer is not intended every bit a substitute for consultation with your dr..

This thermometer must stay in stable ambient (room) temperature for thirty minutes before operating.

Audio fever indicator
Thermometer will point by beeps normal, elevated or high temperature.

Audio fever indicator

Body temperature
Normal body temperature is a range. It varies past site of measurement and it tends to decrease with historic period. It too varies from person to person and fluctuates throughout the day. Therefore, it is important to determine normal temperature ranges.

How to utilise your Braun ThermoScan®
Before taking the temperature, make sure the ear is free from obstructions or backlog earwax.

Do non endeavour to take the reading without a disposable lens filter on – the measuring sensor must be kept protected and make clean from earwax to give authentic readings.

Change the disposable lens filter with each use to ensure hygiene, to continue child safe from cross-contagion and to ensure earwax residues on the dispensable lens filter practice non affect accuracy of the reading.

How to use

Dispensable lens filters
Use a clean disposable aseptic lens filter with each measurement:

  1. To ensure hygienic employ
  2. To protect your kid from cantankerous-contagion
  3. To ensure earwax residues do not impact accuracy of the reading.
Disposable lens filters

Earwax and dirt on the tip of the disposable lens filter, even in microscopic layer, can create an obstacle between the sensor and the infrared heat emitted past the ear and impact the accuracy of the measurement.

Temperature taking hints

  • Supersede the disposable lens filter with every use to maintain hygiene and accuracy.
  • A measurement taken in the correct ear may differ from the measurement taken in the left ear. Therefore, e'er take the temperature in the same ear.
  • The ear must be free from obstructions or excess earwax build-up to take an accurate reading.
  • External factors may influence ear temperatures, including when an individual has:

– been lying on one ear or the other
– had their ears covered
– been exposed to very hot or very cold temperatures, or
– been recently swimming or bathing.
In these cases, remove the individual from the situation and expect 20 minutes prior to taking a temperature.

  • If ear drops or other ear medications accept been placed in the ear canal of i ear, take the temperature in the untreated ear.

Care and cleaning

The probe tip (5) is the most delicate function of the thermometer. Information technology has to be clean and intact to ensure accurate readings.

If the thermometer is accidentally used without a dispensable lens filter, clean the probe tip as follows:

Care and cleaning

Very gently wipe the surface with a cotton wool swab or soft cloth moistened with alcohol. Do not employ cleaners other than booze on the probe tip. Use of other cleaners could damange the tip.

Once the alcohol has stale completely, a new disposable lens filter can be put on and a temperature measurement taken. If the probe tip is damaged, please contact your authorized local service center.

Use a soft, dry cloth to clean the thermometer brandish and production exterior. Practice non use annoying cleaners. Never submerge this thermometer in h2o or any other liquid.
Shop the thermometer and dispensable lens filters in a dry location free from dust and contamination and away from directly sunlight.

Additional disposable lens filters (LF 40) are available at almost stores selling Braun ThermoScan.

Trouble-shooting

Trouble-shooting
Trouble-shooting

Irresolute the temperature scale

Brand sure the thermometer is turned off. Press and hold downward the <> push button. Keep holding down the <> button and after about 3 seconds the display will start to cycle between temperature scales (°C or °F).

Changing the temperature scale

Release the start button when the desired scale is shown. This volition reset the thermometer to the new temperature calibration.

Replacing the battery
The thermometer is supplied with one 3V Lithium cell battery (type 2032). Insert new bombardment when the depression battery symbol appears on the brandish.

The battery door pattern is intended to prevent a minor kid from easily opening the battery door to accost a possible choke hazard. Open up the bombardment compartment by inserting a narrow pointed object such as a ball point pen or paperclip into the small hole above the battery door (viii). While pressing into the hole slowly slide dorsum the battery door with the other hand.

Replacing the battery

To close bombardment door align the tabs along the side of the battery into the battery compartment and slowly slide dorsum into position until the door clicks into its locked position.

Scale
This production has been calibrated at the time of industry. If used according to the use instructions, periodic calibration is non required. If at whatever time, yous question the measuring accuracy, please contact our service representative (run into last page for contact information) or visit www.hot-europe.com/support.

Manufacturing date is given by the LOT number located in the battery compartment.

The outset 3 (3) digits subsequently LOT represent the Julian engagement that the product was manufactured and the next two (2) digits represent the final 2 numbers of the calendar year the product was manufactured. The final identifiers are the letters that represent the manufacturer.

An case: LOT 11614fam, this product has been manufactured on the 116th mean solar day of the year 2014.

Guarantee
EMC tables and Consumer Card are bachelor on our website at world wide web.hot-europe.com/support

For support requests, please visit www.hot-europe.com/back up or observe service contact information on the terminal folio of this manual.

United kingdom of great britain and northern ireland only: This guarantee in no way affects your rights under statutory police force.

Product specifications

Product specifications

If device is not used or stored within specified temperature and humidity ranges the technical accuracy cannot be ensured.

Caution

Subject area to change without notice.
IP22: Protected against solid foreign objects of 12.5 mm diameter and greater. Protected against vertically falling water drops when the device is tilted up to 15 degrees.

EN 12470‑v:2003 Clinical thermometers—Part v: Functioning of infra‑red ear thermometers (with maximum device) ISO 80601‑2‑56:2009 Medical electric equipment— Part ii‑56: Particular requirements for basic prophylactic and essential performance of clinical thermometers for body temperature measurement This product conforms to the provisions of the EC directives 93/42/EEC (Medical Device Directive) and 2011/65/EU (RoHS).

The Braun ThermoScan needs special precautions regarding EMC. For detailed description of EMC requirements please refer to world wide web.hot-europe.com/support.
Portable and mobile RF communications equipment tin affect the Braun ThermoScan.

This product contains batteries and recyclable electronic waste. To protect the environment, exercise not dispose of information technology in the household waste, simply take it to appropriate local collection points.

Ezoic

Questions about your Manual ? Mail service in the comments!

Source: https://manuals.plus/braun/braun-irt3030-thermoscan-3-thermometer-instruction-manual-2

Posted by: graytimit1951.blogspot.com

0 Response to "How To Change The Battery In A Braunthermoscan Model Hm3"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel